General Specifications

Function
pressure balanced 2/2 way externally controlled coaxial valves, NC and NO versions
Media
gaseous, liquid, gelatinous, highly viscous, pasty, contaminated, aggressive, coolant
Body Materials
aluminium, brass, galvanized steel, nickel plated brass, nickel plated steel, without non-ferrous metals, stainless steel
The materials refer to parts in contact with the media.
Seal Materials
NBR, PTFE, FPM, PU, PE, CR, EPDM, special seal materials
Options
function NO, limit switches, manual override, special voltage, coil M 12 x 1, pilot valve, damping, approvals, connections for sensor or pressure gauge, explosion-proof
Remark
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Für den Inhalt dieser Seite ist eine neuere Version von Adobe Flash Player erforderlich.

Adobe Flash Player herunterladen

Valve Types

CFM 08

CFM 08

Ports
CFM threads NPT 3/8
Function
NC
Pressure Range
0-600 psi
cv Value
1.8 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
400 1/min
Switching Time [ms]
opening 70 closing 80
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
0,3
Nominal Voltage
UN DC 24V, UN AC 230V 40-60 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

CFM 08 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

CFM 08 Drawing

Circuit Symbols

MCF 08

MCF 08

Ports
MCF threads NPT 3/8
Function
NC
Pressure Range
0-1500 psi
cv Value
1.8 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
600 1/min
Switching Time [ms]
opening 30-3000 closing 30-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
1,3
Nominal Voltage
UN DC 24V, UN AC 230V 40-60 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

MCF 08 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

Circuit Symbols

VMK 10

VMK 10

Ports
VMK threads NPT 1/4 - NPT 3/4
Function
NC
Pressure Range
0-240 / 0-600 / 0-960 / 0-1500 psi
cv Value
2.9 GPM (> 960 psi 2.4 GPM)
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
680 1/min
Switching Time [ms]
opening 30-3000 closing 50-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VMK 1,7
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VMK 10 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VMK 10 Drawing

Circuit Symbols

VMK / VFK 15

VMK / VFK 15

Ports
VMK threads NPT 3/8 - NPT 3/4
VFK flanges ANSI 150 / 600 / 1500
Function
NC
Pressure Range
0-240 / 0-600 / 0-960 / 0-1500 psi
cv Value
6.6 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
200 1/min
Switching Time [ms]
opening 50-3000 closing 50-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VMK 3,4 VFK 5,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VMK / VFK 15 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VMK 15 Drawing

VFK 15 Drawing

Circuit Symbols

VMK / VFK 20

VMK / VFK 20

Ports
VMK threads NPT 3/4 - NPT 11/4
VFK flanges ANSI 150 / 600 / 1500
Function
NC
Pressure Range
0-240 / 0-600 / 0-960 / 0-1500 psi
cv Value
10.2 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
200 1/min
Switching Time [ms]
opening 50-3000 closing 50-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VMK 4,7 VFK 6,7
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VMK / VFK 20 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VMK 20 Drawing

VFK 20 Drawing

Circuit Symbols

VMK / VFK 25

VMK / VFK 25

Ports
VMK threads NPT 1 - NPT 11/2
VFK flanges ANSI 150 / 600 / 1500
Function
NC
Pressure Range
0-240 / 0-600 / 0-960 / 0-1500 psi
cv Value
15.4 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
200 1/min
Switching Time [ms]
opening 50-3000 closing 50-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VMK 6,7 VFK 9,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VMK / VFK 25 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VMK 25 Drawing

VFK 25 Drawing

Circuit Symbols

VMK / VFK 32

VMK / VFK 32

Ports
VMK threads NPT 11/4 - NPT 11/2
VFK flanges ANSI 150 / 600 / 1500
Function
NC
Pressure Range
0-240 / 0-600 / 0-960 / 0-1500 psi
cv Value
23.1 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
150 1/min
Switching Time [ms]
opening 100-3000 closing 100-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VMK 7,8 VFK 11,6
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VMK / VFK 32 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VMK 32 Drawing

VFK 32 Drawing

Circuit Symbols

VMK / VFK 40

VMK / VFK 40

Ports
VMK threads NPT 11/2 - NPT 2
VFK flanges ANSI 1500
Function
NC
Pressure Range
0-960 / 0-1500 psi
cv Value
35.8 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
150 1/min
Switching Time [ms]
opening 100-3000 closing 100-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VMK 11,3 VFK 13,6
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VMK / VFK 40 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VMK 40 Drawing

VFK 40 Drawing

Circuit Symbols

VMK / VFK 50

VMK / VFK 50

Ports
VMK threads NPT 2
VFK flanges ANSI 1500
Function
NC
Pressure Range
0-960 / 0-1500 psi
cv Value
49.7 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
100 1/min
Switching Time [ms]
opening 150-3000 closing 150-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VMK 12,3 VFK 18,7
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VMK / VFK 50 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VMK 50 Drawing

VFK 50 Drawing

Circuit Symbols

VSV-M / VSV-F 40

VSV-M / VSV-F 40

Ports
VSV-M threads NPT 11/2 - NPT 2, VSV-F flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
35.8 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
150 1/min
Switching Time [ms]
opening 100-3000 closing 100-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-M 7,2 VSV-F 11,4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-M / VSV-F 40 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-M 40 Drawing

VSV-F 40 Drawing

Circuit Symbols

VSV-M / VSV-F 50

VSV-M / VSV-F 50

Ports
VSV-M threads NPT 2, VSV-F flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
49.7 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
100 1/min
Switching Time [ms]
opening 150-3000 closing 150-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-M 11,9 VSV-F 18,2
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-M / VSV-F 50 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-M 50 Drawing

VSV-F 50 Drawing

Circuit Symbols

VSV-F 65

VSV-F 65

Ports
VSV-F flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
78.6 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
50 1/min
Switching Time [ms]
opening 200-3000 closing 200-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-F 20,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-F 65 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-F 65 Drawing

Circuit Symbols

VSV-F 80

VSV-F 80

Ports
VSV-F flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
104.0 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
50 1/min
Switching Time [ms]
opening 200-3000 closing 200-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-F 27,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-F 80 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-F 80 Drawing

Circuit Symbols

VSV-F 100

VSV-F 100

Ports
VSV-F flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
161.8 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
40 1/min
Switching Time [ms]
opening 300-3000 closing 300-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-F 38,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-F 100 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-F 100 Drawing

Circuit Symbols

VSV-F 125

VSV-F 125

Ports
VSV-F flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
228.9 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
30 1/min
Switching Time [ms]
opening 400-3000 closing 400-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-F 51,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-F 125 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-F 125 Drawing

Circuit Symbols

VSV-F 150

VSV-F 150

Ports
VSV-F flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
316.7 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
20 1/min
Switching Time [ms]
opening 600-3000 closing 600-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-F 87,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-F 150 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-F 150 Drawing

Circuit Symbols

VSV-F 200

VSV-F 200

Ports
VSV-F flanges ANSI 150
Function
NC
Pressure Range
0-240 psi
cv Value
520.2 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
10 1/min
Switching Time [ms]
opening 800-3000 closing 800-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-F 159,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-F 200 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-F 200 Drawing

Circuit Symbols

VSV-F 250

VSV-F 250

Ports
VSV-F flanges ANSI 150
Function
NC
Pressure Range
0-240 psi
cv Value
751.4 GPM
Media
gaseous, liquid, highly viscous, gelatinous, pasty, contaminated
Flow Direction
A ⇒ B as marked
Switching Cycles
4 1/min
Switching Time [ms]
opening 1500-3000 closing 1500-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
VSV-F 215,0
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

VSV-F 250 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

VSV-F 250 Drawing

Circuit Symbols

FCF 65

FCF 65

Ports
FCF flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
123.7 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
50 1/min
Switching Time [ms]
opening 250-3000 closing 400-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
FCF 12,5
Additional Equipment
sensor / manometer connection NPT 1/4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

FCF 65 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

FCF 65 Drawing

Circuit Symbols

FCF-K 65

FCF-K 65

Ports
FCF-K flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
113.3 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
50 1/min
Switching Time [ms]
opening 250-3000 closing 400-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
FCF-K 9,2
Additional Equipment
sensor / manometer connection NPT 1/4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

FCF-K 65 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

FCF-K 65 Drawing

Circuit Symbols

FCF 80

FCF 80

Ports
FCF flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
153.7 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
50 1/min
Switching Time [ms]
opening 350-3000 closing 350-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
FCF 14,5
Additional Equipment
sensor / manometer connection NPT 1/4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

FCF 80 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

FCF 80 Drawing

Circuit Symbols

FCF-K 80

FCF-K 80

Ports
FCF-K flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
141.0 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
50 1/min
Switching Time [ms]
opening 350-3000 closing 350-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
FCF-K 11,5
Additional Equipment
sensor / manometer connection NPT 1/4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

FCF-K 80 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

FCF-K 80 Drawing

Circuit Symbols

FCF 100

FCF 100

Ports
FCF flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
248.5 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
40 1/min
Switching Time [ms]
opening 450-3000 closing 300-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
FCF 34,0
Additional Equipment
sensor / manometer connection NPT 1/4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

FCF 100 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

FCF 100 Drawing

Circuit Symbols

FCF-K 100

FCF-K 100

Ports
FCF-K flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
223.1 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
40 1/min
Switching Time [ms]
opening 450-3000 closing 300-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
FCF-K 25,0
Additional Equipment
sensor / manometer connection NPT 1/4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

FCF-K 100 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

FCF-K 100 Drawing

Circuit Symbols

FCF 125

FCF 125

Ports
FCF flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
262.4 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
30 1/min
Switching Time [ms]
opening 700-3000 closing 450-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
FCF 52,0
Additional Equipment
sensor / manometer connection NPT 1/4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

FCF 125 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

FCF 125 Drawing

Circuit Symbols

FCF-K 125

FCF-K 125

Ports
FCF-K flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
cv Value
255.5 GPM
Media
emulsions, oils - neutral gases
Flow Direction
A ⇒ B as marked
Switching Cycles
30 1/min
Switching Time [ms]
opening 700-3000 closing 450-3000
Media Temperature [°F]
direct mounted pilot valve 140
Ambient Temp. [°F]
direct mounted pilot valve 122
Weight [kg]
FCF-K 42,0
Additional Equipment
sensor / manometer connection NPT 1/4
Nominal Voltage
UN DC 24V, UN AC 230V 50 Hz
Power Consumption
DC 4,8 W, AC pick up 11,0 VA holding 8,5 VA
Protection
IP 65 (P54) acc. DIN 40 050
Energized Duty Rating
ED 100%

FCF-K 125 Data Sheet

General Operating Instructions

Declaration of Conformity non-electrical equip. cat. 2

FCF-K 125 Drawing

Circuit Symbols