ports |
1 1/4 - 1 1/2 NPT threads ANSI 150/600/1500 flanges |
function |
NC / NO |
pressure range |
0-240 / 0-600 / 0-960 / 0-1500 psi |
CV value |
20.11 GPM |
media |
gaseous liquid highly viscous gelatinous contaminated |
flow direction |
A B as marked |
switching cycles |
120 1/min |
switching time |
opening 440 ms closing 250 ms |
media temperature |
DC -4 °F — +212 °F
AC -4 °F — +212 °F |
ambient temperature |
DC -4 °F — +176 °F
AC -4 °F — +176 °F |
weight |
MK 13.5 kg FK 17.5 kg |
nominal voltage |
Un 24 V DC +5% / -10%
Un 230 V 40-60 Hz AC +5% / -10%
|
actuation |
DC direct-current magnet AC direct-current magnet with integrated rectifier |
insulation rating |
H 180 °C |
protection |
IP65 |
energized duty rating |
ED 100% |
connection |
plug acc. DIN EN 175301-803, form A, 4 positions x 90°, wire diameter 6-8 mm |
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.