ports |
3/4 - 1 1/4 NPT threads ANSI 150/600 flanges |
function |
NC / NO |
pressure range |
0-240 / 0-600 psi A B max. 600 psi B A max. 240 psi A C max. 600 psi C A max. 600 psi |
CV value |
7.75 GPM |
media |
gaseous liquid highly viscous gelatinous contaminated |
flow direction |
see pressure range |
switching cycles |
150 1/min |
switching time |
opening 110 ms closing 110 ms |
media temperature |
DC -4 °F — +176 °F
AC -4 °F — +176 °F |
ambient temperature |
DC -4 °F — +176 °F
AC -4 °F — +176 °F |
weight |
MK 6.0 kg FK 8.4 kg |
nominal voltage |
Un 24 V DC +5% / -10%
Un 230 V 40-60 Hz AC +5% / -10%
|
actuation |
DC direct-current magnet AC direct-current magnet with integrated rectifier |
insulation rating |
H 180 °C |
protection |
IP65 |
energized duty rating |
ED 100% |
connection |
plug acc. DIN EN 175301-803, form A, 4 positions x 90°, wire diameter 6-8 mm M12x1 connector acc. DESINA / VDMA |
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.