ports | 1/4 - 3/4 NPT threads |
function | NC / NO |
pressure range | 0-240 psi A B max. 240 psi B A max. 240 psi A C max. 240 psi C A max. 240 psi |
CV value | 3.01 GPM |
media | gaseous liquid contaminated |
flow direction | as marked |
switching cycles | 200 1/min |
switching time | opening 80 ms closing 140 ms |
media temperature | DC -40 °C — +104 °F AC -40 °C — +104 °F |
ambient temperature | DC -40 °C — +104 °F AC -40 °C — +104 °F |
weight | 2.2 kg |
nominal voltage |
Un 24 V DC +5% / -10% Un 230 V 40-60 Hz AC +5% / -10% |
actuation | DC direct-current magnet AC direct-current magnet with integrated rectifier |
insulation rating | H 180 °C |
protection | IP65 |
energized duty rating | ED 100% |
connection | terminal box, 3 m flying leads |
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.