co-ax valves inc. USA

Lateral Valves

DRV 25

DRV 25
Data Sheets
General Operating Manual
ports 1 NPT threads
function NC
pressure range vacuum max. 98%
A B Δp max. 30 psi
B A Δp max. 30 psi
A C Δp max. 30 psi
C A Δp max. 30 psi
CV value 14.8 GPM
media gaseous 
flow direction see pressure range
switching cycles 70 1/min
switching time opening 160 ms
closing 100 ms
media temperature DC +14 °F — +176 °F
AC +14 °F — +176 °F
ambient temperature DC +14 °F — +176 °F
AC +14 °F — +176 °F
weight 5.4 kg
nominal voltage Un 24 V DC +5% / -10%
Un 230 V 40-60 Hz AC +5% / -10%
actuation DC direct-current magnet
AC direct-current magnet with integrated rectifier
insulation rating H 180 °C
protection IP65
energized duty rating ED 100%
connection plug acc. DIN EN 175301-803, form A, 4 positions x 90°, wire diameter 6-8 mm

The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

Accessories

electrical connection

electrical connection
connector form A DIN EN 175301-803

Lateral Valves